Condition Investigations of HDPE Pipe In-Service In the United States (Six States)
|
Item Code: SN2474
Date of Publication: 2002
Price: $0.00
|
|
This study consisted of inspecting 39 High Density Polyethylene (HDPE) Pipes located in 6 different states. The diameters of the pipes ranged from 24 in. to 60 in. The inspections consisted of diameter measurements, distress documentation, alignment measurements, and still and video photography. Pipe deflection, distress and misalignment problems are recorded in tables and photographs. A significant percentage of the 39 pipe installations inspected had deflections in excess of 5% or were experiencing joint separation. Cracking and buckling were also identified, but to a lesser degree. The report contains more than 100 tables, graphs and color photographs. This report is also found on DVD021.
Click for more
|
|
|
|
|